Battery Protect 12/24V 100A

$81.00

The Battery Protect 12/24V 100A disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

Out of stock

Brand:

Battery Protect 12/24V 100A

Features:

  • Low Voltage Disconnect
  • Protects Battery From Over-Discharging
  • Can be Used as a Battery Isolator
  • Can be Remotely Controlled from VE.Bus BMS
  • 100Amps

The BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

12/24V Auto Ranging:

The BatteryProtect automatically detects system voltage

Programming Made Easy:

The BatteryProtect can be set to engage / disengage at several different voltages. The seven-segment display will indicate which setting has been chosen.

A Special Setting for Li-ion Batteries:

In this mode, the BatteryProtect can be controlled by the VE.Bus BMS. Note: The BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See the connection diagram in the manual.

Ultra-low Current Consumption:

This is important in the case of Li-ion batteries, especially after low voltage shutdown. Please see the Victron Li-ion battery datasheet and the VE.Bus BMS manual for more information.

Over Voltage Protection:

To prevent damage to sensitive loads due to overvoltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.

Ignition Proof:

No relays but MOSFET switches, and therefore no sparks.

Delayed Alarm Output:

The alarm output is activated if the battery voltage drops below the preset disconnect level for more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short-circuit-proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed Load Disconnect & Delayed Reconnect:

The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

Additional information

Weight 0.55 kg
Dimensions 20 × 8 × 8 cm